AR# 3847

|

WVO7.4, M1.4, 5200:ERROR: baste:266-An extension is required on the "RLOC" parameter for CY_MUX/FDCE

描述

Keywords: RLOC, extension, baste, 5200, map, error, FJKC, CY4, Workview Office

Urgency: Standard

General description:
Implementing a Viewlogic design, MAP may give the following error:

ERROR: baste:266-An extension is required on the "RLOC" parameter for FDCE
symbol "<symbol name>" (output singnal=<netname>).

The same error may occur for CY_MUX symbols.

The error is generated because of an RLOC=R0C0 attribute on the FDCE within an
FJKC symbol.

This error will occur if a 'Flattened' netlist was generated from the Viewlogic
EDIF Netlist writer instead of a 'Hierarchical' one.

解决方案

Make sure that the EDIF file is generated with the following options:

1. Netlist Options: Hierarchical (default)
2. LEVEL = XILINX or "Xilinx M1"