AR# 56682

|

MIG 7 Series QDRII+ - Write Calibration might fail for x18 multiple component designs when K/K# is not located in the same byte lane as write data

描述

Version Found: v2.0
Version Resolved: See (Xilinx Answer 54025)

A Write Calibration update is required for MIG 7 Series QDRII+ designs due to potential calibration failures when centering data not located in the same byte lane as the K/K# clock. Single components are not affected by this issue. 

解决方案

For x18 multi-component designs (i.e., 36-bit data width, 2 x18 components), Write Calibration is not performed for write data not located in the same byte group as K/K# of the first component. Instead of performing calibration for this data group, the algorithm jumps to the second component and eventually fails during Write Calibration.

To work around the Write Calibration issue, the attached patch must be applied.

Note: Instructions for applying the patch for Vivado, ISE, and EDK users can be found in the readme.txt file located in the patch ZIP.

Revision History
08/16/2013 - Updated patch with latch fix from (Xilinx Answer 57148)
07/11/2013 - Initial release

附件

文件名 文件大小 File Type
AR56682.zip 45 KB ZIP

链接问答记录

主要问答记录

Answer Number 问答标题 问题版本 已解决问题的版本
54025 MIG 7 Series - IP Release Notes and Known Issues for Vivado N/A N/A
AR# 56682
日期 08/29/2013
状态 Active
Type 已知问题
器件
IP
People Also Viewed