I have a successfully routed Vivado 2015.2 design. However when the design is migrated to Vivado 2015.3, it has the following routing errors:
Nets with Routing Errors:
IBUFDS_MgtRefClk_148_35_n_5
Conflicting Routing Nodes -- only the first 10 are listed, use -show_all to get the full list:
CLK_HROW_TOP_R_X95Y182/CLK_HROW_CK_BUFHCLK_L7
CLK_HROW_TOP_R_X95Y182/CLK_HROW_CK_HCLK_OUT_L7 (BUFHCE_X0Y43/O)
CLK_HROW_TOP_R_X95Y182/CLK_HROW_CK_MUX_OUT_L7 (BUFHCE_X0Y43/I)
INT_R_X39Y164/FAN_ALT2
INT_R_X39Y164/FAN_ALT5
INT_R_X39Y164/FAN_BOUNCE2
INT_R_X39Y164/FAN_BOUNCE5
INT_R_X39Y166/FAN_ALT2
INT_R_X39Y166/FAN_ALT5
INT_R_X39Y166/FAN_BOUNCE2
Why is this happening?
In the error message above, a change in opt_design causes the routing issue. opt_design is moving a IBUFDS_GTE2 -> BUFG -> LUT connection to a IBUFDS_GTE2 -> LUT connection.
This change causes a new BUFHCE global clock resource to be used, but not counted as the IBUFDS_GTE2 -> LUT connection is not a global clock.
This fails routing instead of failing in place_design.
To work around this issue, the following parameter can be set:
set_param logicopt.enableSplitBUFGNonSeqLoads 0
Alternatively, a DONT_TOUCH constraint can be used on the affected nets.
This issue has been resolved for the 2016.1 version of Vivado.