AR# 72166

|

2018.2/3 Zynq UltraScale+ MPSoC VCU - Why does the VCU hang when trying to flush multiple times when closing a file?

描述

Why does the VCU hang when trying to flush multiple times when closing a file?

An empty frame can cause the VCU to flush. If an empty frame occurs as the last frame before the application closes, it could result in 2 flushes, which will cause the VCU to hang.

解决方案

This is a known issue with the Zynq UltraScale+ MPSoC VCU - LogiCORE H.264/H.265 Video Codec Unit (VCU) that can occur when the application is shutting down and a flush was already issued.

The fixes below will cause the application to issue an exception and close instead of hanging.

  • 2018.2 - Users can download the PetaLinux Recipes and Patch files from (Xilinx Answer 71798) to work around this issue.
  • 2018.3 - Users can download the PetaLinux Recipes and Patch files from (Xilinx Answer 71798) to work around this issue.
  • 2019.1 - This issue is resolved in the 2019.1 release and later versions.